Description
Fluke TiS40+ Thermal Camera Repair
The Fluke TiS40+ is a Performance-series thermal imager – the workhorse tier, simpler optics and a fixed or manual focus, built to be carried daily by technicians who need a reliable image rather than the highest resolution available. Simpler construction means the faults concentrate in the parts that get handled.
June Company’s certified technicians repair the Fluke TiS40+ for electricians, HVAC technicians, maintenance crews, and facilities teams. Every imager is repaired at component level and its temperature accuracy verified against reference standards before it ships back, with the measured results documented.
Common Fluke TiS40+ problems we fix
- Focus mechanism stiff or slipping.
- Temperature readings drifted – the measurement path rather than the image – a picture that looks fine can still be reporting the wrong number.
- Images not saving or SD card not recognised.
- Laser pointer failure.
- Battery will not hold charge or unit will not power on – the pack, the charging circuit and the power section, tested separately.
- Display or touchscreen failure.
- Image degrading between shutter cycles – the internal NUC shutter, which recalibrates the detector every few minutes – when it sticks the image drifts and blotches until the unit is power-cycled.
- Dead pixels or fixed pattern noise – microbolometer detector faults, which show as permanent spots or a grid pattern that no amount of re-focusing clears.
FAQs
Is an entry-level imager economical to repair? Often yes – the common faults here are batteries, displays and shutters rather than detectors. The evaluation is free and tells you before you commit.
What if it is not worth repairing? We say so in the quote. The evaluation is free and there is no obligation to proceed.
Every repair carries a 90-day parts-and-labor warranty, with a firm quote before any work begins. Email us or submit a service request.





Reviews
There are no reviews yet.