Description
Tettex 3691 Current Burden Repair
The Tettex 3691 is a current burden — a precision reference burden used when testing and calibrating current transformers, providing the defined load the CT sees during accuracy testing. As a precision standard rather than an active instrument, what matters is the stability and accuracy of its burden value, and that’s where service focuses.
June Company repairs and calibrates the Tettex 3691 for metrology labs and CT testing teams.
Common Tettex 3691 problems we fix
- Burden value out of tolerance — drift in the precision burden elements, the critical fault on a reference standard, restored and recalibrated to defined value.
- Connection/terminal faults — worn or damaged terminals affecting the burden presented, repaired.
- Switching faults on multi-value units — the selection mechanism between burden values.
- Physical or contact damage from field handling.
FAQs
My burden drifted out of tolerance — fixable? Yes. We service the burden elements and recalibrate to the defined value so your CT accuracy testing is valid again, documented with a NIST-traceable certificate.
Do you certify the burden value? Yes — verified against our reference standards with documented results.
Every repair includes NIST-traceable calibration and a 90-day parts-and-labor warranty. Email us or submit a service request.
Brand
Tettex Instruments Repair
Tettex specializes in providing high-precision measurement instruments and test equipment for electrical insulating materials, components, and systems. Their products are widely used in industries such as power generation, transmission, and distribution, as well as in laboratories and research institutions. Here are some key Tettex products and their functionalities:
Capacitance and Dissipation/Power Factor Testers:
2840 Precision Tan Delta Bridge: Measures the dissipation factor (tan delta) and capacitance of electrical insulating materials and systems, providing insights into the condition of insulation and detecting aging or deterioration.
2818/2820 Portable Tan Delta Testers: Portable devices for measuring the dissipation factor and capacitance in the field, used for on-site testing of transformers, bushings, and cables.
Dielectric Response Analyzers:
IDAX 300 Insulation Diagnostic System: Analyzes the dielectric response of insulation materials in power transformers and other high-voltage equipment to assess their condition and predict remaining life.
Partial Discharge Testers:
9520/9530 Partial Discharge Detectors: Instruments for detecting and analyzing partial discharges in high-voltage equipment, helping to identify insulation defects and prevent potential failures.
Transformer Turns Ratio Testers:
2293 Automatic Transformer Turns Ratio Meter: Measures the turns ratio of power and distribution transformers, ensuring the correct operation and detecting possible winding issues.
High Voltage Schering Bridges:
2831 High Voltage Schering Bridge: Used for precise measurement of capacitance and dielectric losses in high-voltage insulation systems, essential for evaluating the quality and performance of insulating materials.
Frequency Response Analyzers:
2850/2856 Frequency Response Analyzer: Analyzes the frequency response of electrical insulating materials and systems, providing detailed information about their dielectric properties over a wide frequency range.
Resistivity Meters:
6517A Electrometer/High Resistance Meter: Measures the resistivity of insulating materials, ensuring they meet the required specifications for high-voltage applications.
Impulse Voltage Test Systems:
PIM 100 Impulse Voltage Test System: Generates and measures high-voltage impulses to test the insulation strength and withstand capabilities of electrical components and systems.
Cable Test Systems:
7260 Cable Fault Locator: Locates faults in high-voltage cables, helping to minimize downtime and repair costs by pinpointing the exact location of defects.
Dielectric Material Testers:
2828/2829 Dielectric Material Testers: Evaluate the dielectric properties of various insulating materials, ensuring they meet industry standards and performance requirements.
Tettex products are known for their accuracy, reliability, and advanced technology, making them essential tools for ensuring the safety, performance, and longevity of electrical power systems and insulating materials.
Shipping & Returns
Packing your equipment. You are responsible for packaging equipment adequately for transit. We strongly recommend the original manufacturer’s case, or double-boxing with at least two inches of shock-absorbing material on all six sides. We return your equipment in the packaging it arrived in, so please send it in packaging that will survive the return trip as well. If your packaging is damaged or inadequate for the return, we will substitute suitable packaging and may charge the cost of materials.
Insurance. Equipment is not insured by June Company while in transit. We strongly recommend insuring your shipment for its full replacement value.
Risk of loss. Risk of loss remains with you until your equipment is received at our facility, and transfers back to you when your repaired unit is delivered to the carrier (F.O.B. shipping point). June Company is not responsible for equipment lost, delayed, misdelivered, or damaged in transit, in either direction.
Return label. A prepaid and preprinted return shipping label should be included with your shipment. If one is not included, we will provide one.
Transit damage. Damage occurring in transit is the responsibility of the carrier. It is not a warranty defect and is not covered by the 90-day repair warranty. Any claim must be filed by you with the carrier; we will supply photographs and documentation to support it at no charge.
Full details: Terms & Conditions, Section 6 · Return Policy