Fluke Oscilloscope Calibrator Repair (5800A, 9500B)

Status: 9500B Current Production — 5800A / 5820A Discontinued

Overview

Fluke oscilloscope calibrators provide automated, traceable calibration for oscilloscopes ranging from handheld models to high-bandwidth bench instruments. The 9500B delivers leveled sine waves to 6 GHz and fast edges for bandwidth and timing verification. The legacy 5800A and 5820A are still widely deployed in military and aerospace calibration programs where long-term platform stability is valued.

Specifications

Parameter Value
Frequency Range Up to 6 GHz (9500B), up to 2.1 GHz (5800A)
Edge Speed <175 ps (9500B)
Amplitude Range 1 mV to 6 V peak-to-peak
Key Features Fully automated oscilloscope calibration, leveled sine output, rise/fall time generation, time marker output, impedance verification, MET/CAL compatible

Models We Repair

Select your model below to request a repair. If your exact model isn’t listed, choose the closest match — the evaluation and repair process is the same across all Fluke Oscilloscope Calibrators configurations.

Model Description Service
Fluke 9500B Oscilloscope calibrator, 6 GHz, fully automated Request Repair
Fluke 5800A Oscilloscope calibration workstation (discontinued) Request Repair
Fluke 5820A Oscilloscope calibrator (discontinued) Request Repair

Common Fluke Oscilloscope Calibrators Failures We Repair

  • Leveled sine output amplitude drift at high frequencies
  • Fast edge generator degradation reducing rise time performance
  • Attenuator switching matrix contact resistance changes
  • GPIB interface board failures preventing automated calibration sequences
  • Internal reference oscillator frequency drift
  • Power supply regulation faults under rapid output switching

Our technicians perform component-level diagnostics on every Fluke Oscilloscope Calibrators unit. We don’t just replace boards — we identify and repair the specific failed components, saving you the cost of full module replacements when possible.

Calibration

Every Fluke Oscilloscope Calibrators repair includes NIST-traceable calibration. We verify all primary output and measurement functions against our reference standards and provide a detailed calibration certificate documenting measured performance against the manufacturer’s published specifications.

Who Uses the Fluke Oscilloscope Calibrators?

The Fluke 5800A / 5820A / 9500B Oscilloscope Calibrators are used by calibration laboratories, military electronics maintenance, aerospace test facilities, and oscilloscope manufacturers.

Our Repair Process

  1. Ship Your Instrument: Send your Fluke Oscilloscope Calibrators to our facility from anywhere in the US. We provide prepaid shipping labels on request.
  2. Free Evaluation: Our technicians perform a complete diagnostic assessment and provide a firm, no-obligation repair quote.
  3. Expert Repair: Upon approval, we perform component-level repair using OEM-grade parts.
  4. NIST-Traceable Calibration: Full calibration with documented results across all critical parameters.
  5. Return Shipment: Your instrument is securely packaged and returned with calibration certificate, repair documentation, and our 90-day warranty.

Request a Repair

Contact us for professional Fluke Oscilloscope Calibrators repair and calibration. Our team is ready to evaluate your instrument and provide a no-obligation quote.

Email: info@junecompany.com | All repairs include a 90-day parts and labor warranty.