Status: 700G / 700P Current Production — Controllers Vary
Overview
Fluke 700G precision pressure gauges and 700P interchangeable pressure modules extend the measurement range of Fluke process calibrators. The 700G gauges provide standalone reference-grade pressure measurement, while 700P modules plug directly into the 725, 753, 754, and other process calibrators. The 7250/7252 and PPC4E pressure controllers provide automated pressure generation and control for lab-based calibration systems.
Specifications
| Parameter | Value |
|---|---|
| 700G Range | -14 psi to 10,000 psi (model dependent) |
| 700G Accuracy | 0.05% FS |
| 700P Range | Vacuum to 10,000 psi (module dependent) |
| 7250/PPC4E | Automated pressure control for laboratory calibration |
| Key Features | Interchangeable pressure modules, standalone precision gauges, automated pressure control |
Models We Repair
Select your model below to request a repair. If your exact model isn’t listed, choose the closest match — the evaluation and repair process is the same across all Fluke Pressure Modules and Controllers configurations.
| Model | Description | Service |
|---|---|---|
| Fluke 700P Pressure Module | Interchangeable pressure module for process calibrators | Request Repair |
| Fluke 700P-EX Pressure Module | Intrinsically safe pressure module | Request Repair |
| Fluke 750 Pressure Module | Legacy pressure module | Request Repair |
| Fluke 700G Series | Precision pressure gauge (multiple range models) | Request Repair |
| Fluke 7250 | Pressure controller for laboratory calibration | Request Repair |
| Fluke 7252 | Pressure controller for laboratory calibration | Request Repair |
| Fluke PPC4E | Pressure controller/calibrator for primary standards | Request Repair |
| Fluke 6270A | Pressure controller/calibrator | Request Repair |
Common Fluke Pressure Modules and Controllers Failures We Repair
- Pressure sensor drift from overpressure events or thermal cycling
- Module connector pin corrosion from field environment exposure
- Internal burst disc failure from overpressure
- Controller servo valve wear reducing pressure stability
- Battery degradation on 700G portable gauges
Our technicians perform component-level diagnostics on every Fluke Pressure Modules and Controllers unit. We don’t just replace boards — we identify and repair the specific failed components, saving you the cost of full module replacements when possible.
Calibration
Every Fluke Pressure Modules and Controllers repair includes NIST-traceable calibration. We verify all primary output and measurement functions against our reference standards and provide a detailed calibration certificate documenting measured performance against the manufacturer’s published specifications.
Who Uses the Fluke Pressure Modules and Controllers?
The Fluke 700G / 700P Pressure Modules and 7250 / PPC4E Pressure Controllers are used by pressure calibration laboratories, process instrumentation, aerospace pressure testing, oil and gas, and pharmaceutical manufacturing.
Our Repair Process
- Ship Your Instrument: Send your Fluke Pressure Modules and Controllers to our facility from anywhere in the US. We provide prepaid shipping labels on request.
- Free Evaluation: Our technicians perform a complete diagnostic assessment and provide a firm, no-obligation repair quote.
- Expert Repair: Upon approval, we perform component-level repair using OEM-grade parts.
- NIST-Traceable Calibration: Full calibration with documented results across all critical parameters.
- Return Shipment: Your instrument is securely packaged and returned with calibration certificate, repair documentation, and our 90-day warranty.
Request a Repair
Contact us for professional Fluke Pressure Modules and Controllers repair and calibration. Our team is ready to evaluate your instrument and provide a no-obligation quote.