Fluke TiR Series Building Diagnostic Thermal Camera Repair

Status: All Discontinued — we still repair and calibrate every Fluke TiR Series building diagnostic camera.

Common Fluke TiR Series Problems We Fix

  • Temperature readings inaccurate / IR detector drift
  • No image, blurred image, or won’t focus
  • TiR3 / TiR4 FlexCam: articulating lens cable failure
  • Dead or faded display / pixel loss
  • Battery won’t hold a charge or won’t power on
  • Visible camera / IR-Fusion misaligned or not working
  • Won’t save images / memory card slot not working
  • Parts no longer available from Fluke

Don’t see your exact problem? We repair all TiR Series faults — email us and describe what’s happening.

Fluke TiR Series Models We Repair

Model Description Service
Fluke TiR125 320×240, building + industrial, IR-Fusion Request Repair
Fluke TiR110 160×120, building diagnostics, IR-Fusion Request Repair
Fluke TiR105 160×120, building diagnostics Request Repair
Fluke TiR32 320×240, premium building diagnostic camera Request Repair
Fluke TiR29 160×120, building diagnostics Request Repair
Fluke TiR27 240×180, building diagnostics Request Repair
Fluke TiR4 160×120, FlexCam articulating design Request Repair
Fluke TiR4FT FlexCam with 20mm wide-angle lens Request Repair
Fluke TiR3 160×120, FlexCam articulating design Request Repair
Fluke TiR3FT FlexCam with 20mm wide-angle lens Request Repair

How to Send In Your Fluke TiR Camera

  1. Tell us what’s wrong. Email us or submit a service request with your model and the problem.
  2. Ship it to us. Send your camera from anywhere in the US — we provide prepaid shipping labels on request.
  3. Get a firm quote. We evaluate it and send a no-obligation repair quote. No work is done until you approve.

Email: info@junecompany.com  |  All repairs include NIST-traceable calibration and a 90-day parts-and-labor warranty.

Frequently Asked Questions

Do you still repair these discontinued Fluke TiR cameras?

Yes. The whole TiR line is out of production, but we repair and recalibrate these building diagnostic cameras regularly — many consultants and energy auditors still rely on them, and repair beats replacement.

Can you get parts for cameras Fluke no longer supports?

In most cases, yes. We use component-level repair and salvaged or equivalent parts to restore cameras the manufacturer no longer services.

How much does TiR Series repair cost?

Repairs start with a flat evaluation fee that’s credited toward your repair cost. After we diagnose the camera, you get a firm quote before any work begins — no surprises.

My TiR3 / TiR4 FlexCam lens stopped working — can you fix it?

Yes. FlexCam articulating-lens cable failures from repeated flexing are a known TiR3/TiR4 fault and a common repair, restored so the articulating head works again.

My camera’s temperature readings have drifted — can you recalibrate it?

Yes. IR detector drift is the most common TiR fault. We recalibrate against blackbody reference sources across the full range, with NIST-traceable results on a certificate.

The display or visible/IR-Fusion camera isn’t working — is that repairable?

Yes. Display fading, pixel loss, and visible-camera or IR-Fusion alignment faults are all routine TiR repairs.

What if my exact model isn’t listed?

We service every TiR configuration, including the FlexCam and FT wide-angle variants. If your model isn’t in the table, pick the closest match or email us — the process is the same.

Who uses the Fluke TiR Series?

Building envelope consultants, energy auditors, roofing contractors, HVAC commissioning engineers, home inspectors, and moisture remediation specialists rely on the TiR line for building diagnostic thermography.

See also our Fluke Ti legacy thermal camera repair, Fluke TiS Series repair, and Fluke TiX Series repair pages, or browse all thermal camera repair services.