Status: 5560A / 5550A / 5540A Current Production — 5500A / 5502A / 5520A Discontinued. We repair and calibrate all of them.
Common Fluke 5500 Series Problems We Fix
- Output out of tolerance (voltage, current, or resistance)
- No output or unstable / drifting output on one or more functions
- Won’t power on or intermittent power faults
- Dead or faded front-panel display (common on 5500A / 5502A)
- Relay or range-switching faults from high lab throughput
- Thermocouple / temperature simulation reading inaccurate
- Won’t communicate over GPIB / RS-232 (MET/CAL automation fails)
- Scope calibration output not working
Don’t see your exact problem? We repair all 5500 Series faults — email us and describe what’s happening.
Fluke 5500 Series Models We Repair
| Model | Description | Service |
|---|---|---|
| Fluke 5560A | High-performance calibrator, 2 GHz scope cal, 30A continuous | Request Repair |
| Fluke 5550A | Performance calibrator, 1 GHz scope cal, 30A continuous | Request Repair |
| Fluke 5540A | Standard calibrator, 600 MHz scope cal, 30A continuous | Request Repair |
| Fluke 5520A | Multi-product calibrator (discontinued, replaced by 5550A) | Request Repair |
| Fluke 5502A | Multi-product calibrator (discontinued) | Request Repair |
| Fluke 5500A | Original multi-product calibrator (discontinued) | Request Repair |
| Fluke 5080A | Calibrates digital and analog meters up to 800 mA | Request Repair |
How to Send In Your Fluke 5500 Series
- Tell us what’s wrong. Email us or submit a service request with your model and the problem.
- Ship it to us. Send your unit from anywhere in the US — we provide prepaid shipping labels on request.
- Get a firm quote. We evaluate it and send a no-obligation repair quote. No work is done until you approve.
Email: info@junecompany.com | All repairs include NIST-traceable calibration and a 90-day parts-and-labor warranty.
Frequently Asked Questions
How much does Fluke 5500 Series repair cost?
Repairs start with a flat evaluation fee that’s credited toward your repair cost. After we diagnose the unit, you get a firm quote before any work begins — no surprises.
How long does the repair take?
Most 5500 Series repairs are finished within 5–10 business days of arrival. Because these are reference calibrators, we can discuss expedited turnaround if your lab is down.
My calibrator’s output is out of tolerance — can you bring it back into spec?
Yes. Output-amplifier degradation and drift that push voltage, current, or resistance out of tolerance are the most common 5500 Series repairs, restored and verified against our reference standards.
Do you still repair the discontinued 5500A, 5502A, and 5520A?
Yes. These legacy calibrators are fully supported for repair — including front-panel display failures common on the 5500A and 5502A — even though they’re no longer in production.
Can you fix GPIB/RS-232 faults that break MET/CAL automation?
Yes. Communication board faults that stop GPIB or RS-232 control are a common repair, restored so your automated MET/CAL procedures run again.
Is the repair NIST-traceable, and do I get a certificate?
Yes. Every repair includes NIST-traceable calibration of the primary output and measurement functions, with a documented certificate against Fluke’s published specifications — essential for a reference standard in your lab.
What if my exact model isn’t listed?
We service every 5500 Series configuration. If your model isn’t in the table, pick the closest match or email us — the process is the same.
Who uses the Fluke 5500 Series?
Calibration laboratories, metrology departments, military and government standards labs, aerospace calibration facilities, and third-party calibration providers rely on the 5500 Series as their bench reference for multi-product calibration.
See also our Fluke 5700 Series repair, Fluke oscilloscope calibrator repair, and Fluke electrical tester calibrator repair pages, or browse all calibrator repair services.