Fluke Power Quality Calibrator Repair (6100, 6105, 6135)

Status: 6105A / 6135A Current Production — 6100A / 6100B Discontinued. We repair and calibrate all of them.

Common Fluke Power Quality Calibrator Problems We Fix

  • Output out of tolerance (voltage, current, or power)
  • No output or unstable output on one or more phases
  • Phase angle accuracy drift on three-phase output
  • Harmonic generation distorted at high harmonic orders
  • Power amplifier / output stage failure under high current
  • Won’t power on / touchscreen or front-panel fault (6105A / 6135A)
  • Won’t communicate (automated cal sequences fail)
  • Overheating / cooling fan fault

Don’t see your exact problem? We repair all Fluke power quality calibrator faults — email us and describe what’s happening.

Fluke Power Quality Calibrator Models We Repair

Model Description Service
Fluke 6105A Electrical power quality calibrator, 4-phase, harmonics, flicker Request Repair
Fluke 6135A Phasor measurement calibration system for PMU calibration Request Repair
Fluke 6100B Power quality calibrator (discontinued) Request Repair
Fluke 6100A Power quality calibrator (discontinued) Request Repair
Fluke 6003A Three-phase electrical calibrator for power and energy meters Request Repair

How to Send In Your Fluke Power Quality Calibrator

  1. Tell us what’s wrong. Email us or submit a service request with your model and the problem.
  2. Ship it to us. Send your unit from anywhere in the US — we provide prepaid shipping labels on request.
  3. Get a firm quote. We evaluate it and send a no-obligation repair quote. No work is done until you approve.

Email: info@junecompany.com  |  All repairs include NIST-traceable calibration and a 90-day parts-and-labor warranty.

Frequently Asked Questions

How much does Fluke power quality calibrator repair cost?

Repairs start with a flat evaluation fee that’s credited toward your repair cost. After we diagnose the unit, you get a firm quote before any work begins — no surprises.

How long does the repair take?

Most 6100, 6105A, and 6135A repairs are finished within 5–10 business days of arrival. Because these are reference calibrators, we can discuss expedited turnaround if your lab is down.

My calibrator’s output is out of tolerance — can you bring it back into spec?

Yes. Output-stage degradation and phase-angle drift are the most common faults on these units. We repair the cause and verify multi-phase voltage, current, and power output against our reference standards.

Do you repair the 6135A PMU / phasor calibration functions?

Yes. We service the 6135A’s phasor measurement unit calibration capability, restoring and verifying the timing and phase accuracy that PMU calibration depends on.

Do you still repair the discontinued 6100A and 6100B?

Yes. These legacy power quality calibrators are fully supported for repair and recalibration alongside the current 6105A and 6135A.

Can you fix faults that break automated calibration sequences?

Yes. Communication interface faults that stop MET/CAL automation are a common repair, restored so your automated procedures run again.

Is the repair NIST-traceable, and do I get a certificate?

Yes. Every repair includes NIST-traceable calibration of the output functions, documented on a certificate against Fluke’s published specifications — essential for a metering-lab reference instrument.

Who uses Fluke power quality calibrators?

Utility metering laboratories, protective relay calibration teams, energy meter manufacturers, and grid operator metrology departments rely on the 6003A, 6100, 6105A, and 6135A.

See also our Fluke 5500 Series repair, Fluke 5700 Series repair, and Fluke electrical tester calibrator repair pages, or browse all calibrator repair services.