Status: 789 / 787B Current Production ā 773 Current Production
Overview
Fluke ProcessMeters combine a digital multimeter with a loop calibrator in a single handheld instrument, eliminating the need to carry separate tools for process instrumentation work. The 789 provides the most comprehensive feature set with mA source, simulate, and measure capability plus 24 V loop supply and HART compatibility. The 787B offers core mA sourcing and measurement with DMM functions. The 773 Process Clamp Meter adds non-contact 4ā20 mA measurement through a clamp jaw, enabling loop signal checking without breaking the loop. All models include standard DMM functions for voltage, resistance, continuity, and frequency measurement.
Specifications
| Parameter | Value |
|---|---|
| mA Source | 0 to 24 mA with 0.015% accuracy (789) |
| mA Measure | 0 to 24 mA |
| 24V Loop Supply | Built-in (789) |
| DC Voltage | 0.1 mV to 1000 V |
| Resistance | 0.1 Ī© to 40 MĪ© |
| 773 Clamp | Non-contact 4ā20 mA measurement without breaking the loop |
| Safety Rating | CAT III 1000 V / CAT IV 600 V (787B/789) |
| Key Features | Combined DMM + loop calibrator, mA source/simulate/measure, 24V loop supply (789), non-contact mA (773), 25% auto-step, Min/Max |
Models We Service
Select your model below to request repair or calibration. If your exact model isn’t listed, choose the closest match ā the evaluation and repair process is the same across all Fluke ProcessMeters configurations.
| Model | Description | Service |
|---|---|---|
| Fluke 789 | ProcessMeter ā DMM + mA calibrator with 24V loop supply | Request Repair |
| Fluke 787B | ProcessMeter ā DMM + mA calibrator | Request Repair |
| Fluke 787 | ProcessMeter (original model) | Request Repair |
| Fluke 773 | Process clamp meter ā non-contact 4-20 mA measurement | Request Repair |
Common Fluke ProcessMeters Failures We Repair
- mA sourcing circuit drift causing out-of-tolerance loop calibrations
- Input protection circuit damage from voltage applied to mA terminals
- Rotary switch contact degradation from frequent function changes
- Battery compartment corrosion from field moisture
- LCD display segment failure
- 773: Clamp jaw alignment degradation affecting non-contact measurement
- 789: 24V loop supply voltage regulation drift
Our technicians perform component-level diagnostics on every Fluke ProcessMeters unit. We don’t just replace boards ā we identify and repair the specific failed components, saving you the cost of full module replacements when possible.
Calibration
Every Fluke ProcessMeters repair includes NIST-traceable calibration. We verify all measurement functions ā DC/AC voltage, DC/AC current, resistance, and any additional functions ā against our reference standards and provide a detailed calibration certificate documenting measured performance against the manufacturer’s published specifications.
Who Uses the Fluke ProcessMeters?
The Fluke 787B / 789 / 773 ProcessMeters and Process Clamp Meters are used by process instrumentation technicians, industrial maintenance, oil and gas field operations, pharmaceutical process control, water treatment, and HVAC control system technicians.
Our Repair Process
- Ship Your Instrument: Send your Fluke ProcessMeters to our facility from anywhere in the US. We provide prepaid shipping labels on request.
- Free Evaluation: Our technicians perform a complete diagnostic assessment and provide a firm, no-obligation repair quote.
- Expert Repair: Upon approval, we perform component-level repair using OEM-grade parts.
- NIST-Traceable Calibration: Full calibration with documented results across all critical parameters.
- Return Shipment: Your instrument is securely packaged and returned with calibration certificate, repair documentation, and our 90-day warranty.
Request a Repair
Contact us for professional Fluke ProcessMeters repair and calibration. Our team is ready to evaluate your instrument and provide a no-obligation quote.
Email: info@junecompany.com | All repairs include a 90-day parts and labor warranty.