Fluke Ti95 Thermal Imager Repair

$245.00

🛡️ 90-Day Warranty ✓ Fee Credited to Repair ⚡ No Forms Needed

Ship your Fluke Infrared Camera Ti95 to June Company for professional repair and NIST-traceable calibration. Critical for predictive maintenance teams, electrical inspectors, building envelope consultants, and HVAC troubleshooters who depend on reliable thermal imager performance.

đź“‹ How It Works

  1. Submit Request – Pay evaluation fee & provide equipment details
  2. Ship to Us – Send your equipment to our Oregon facility
  3. We Evaluate – Detailed diagnosis & repair estimate
  4. Fee Credited – Your evaluation fee applies to repair cost
  5. We Repair – Professional repair with 90-day warranty
  • đź”§ Fast Turnaround: Most repairs are completed within 1–3 business days.
  • 📏 Precision Calibration: NIST-traceable calibrations included for most repairs.
  • 🛡️ Warranty: 90-day warranty on all repairs.
  • 📝 Transparency: Detailed evaluation and repair estimate before work begins.
âś“ Evaluation Fee Credited Toward Repair

This evaluation fee is applied as credit toward your final repair cost. After we evaluate your equipment, you'll receive a detailed estimate before any repair work begins.

Description

Fluke Ti95 Thermal Imager Repair

The Fluke Ti95 is a general-purpose handheld thermal imager, the tier most industrial thermography actually runs on – enough resolution and accuracy for electrical inspection, motor and bearing checks and mechanical surveys, in a body designed to be carried around a plant all day.

Certified technicians at June Company service the Fluke Ti95 for maintenance technicians, electrical contractors, predictive maintenance teams, and plant engineers. Every imager is repaired at component level and its temperature accuracy verified against reference standards before it ships back, with the measured results documented.

Common Fluke Ti95 problems we fix

  • Visible-light camera or IR-Fusion blending faults.
  • Display or touchscreen failure.
  • Battery will not hold charge or unit will not power on – the pack, the charging circuit and the power section, tested separately.
  • Images not saving or SD card not recognised.
  • Damaged germanium lens or coating – scratches and coating loss, which reduce transmission and shift readings low.
  • Dead pixels or fixed pattern noise – microbolometer detector faults, which show as permanent spots or a grid pattern that no amount of re-focusing clears.
  • Image degrading between shutter cycles – the internal NUC shutter, which recalibrates the detector every few minutes – when it sticks the image drifts and blotches until the unit is power-cycled.
  • Temperature readings drifted – the measurement path rather than the image – a picture that looks fine can still be reporting the wrong number.
  • Focus mechanism stiff, slipping, or failing to hold.

FAQs

How long does a repair take? Most are completed in 5-10 business days, with a firm quote after evaluation and before any work starts.

My readings are low across the board but the image looks normal – why? Often lens transmission rather than the detector. A scratched or degraded germanium lens passes less energy and everything reads cold.

Every repair carries a 90-day parts-and-labor warranty, with a firm quote before any work begins. Email us or submit a service request.