Get your Fluke DTX-CHA002 repaired with certified accuracy and a 90-day warranty. Our repair process covers diagnostics through final measurement uncertainty verification.

📋 How It Works

  1. Submit Request – Pay evaluation fee & provide equipment details
  2. Ship to Us – Send your equipment to our Oregon facility
  3. We Evaluate – Detailed diagnosis & repair estimate
  4. Fee Credited – Your evaluation fee applies to repair cost
  5. We Repair – Professional repair with 90-day warranty
  • 🔧 Fast Turnaround: Most repairs are completed within 1–3 business days.
  • 📏 Precision Calibration: NIST-traceable calibrations included for most repairs.
  • 🛡️ Warranty: 90-day warranty on all repairs.
  • 📝 Transparency: Detailed evaluation and repair estimate before work begins.
✓ Evaluation Fee Credited Toward Repair

This evaluation fee is applied as credit toward your final repair cost. After we evaluate your equipment, you'll receive a detailed estimate before any repair work begins.

Description

Fluke DTX-CHA002 Calibration

The Fluke DTX-CHA002 is a copper cable certifier, and its calibration is what makes its pass and fail verdicts defensible. The instrument issues certificates that other people rely on, so verification covers both the main and remote units and the adapters they test through – a worn adapter produces failures indistinguishable from genuinely faulty cabling.

June Company’s technicians calibrate the Fluke DTX-CHA002 for network installers, structured cabling contractors, data centre teams, and certification bodies. Every point is measured against reference standards, with as-found readings recorded before any adjustment and as-left readings afterwards, so you can see what condition the instrument was actually in when it arrived.

What we verify on the Fluke DTX-CHA002

  • Permanent link and channel adapters – a consumable interface whose wear shows up as failed cable rather than failed tester.
  • Insertion loss and return loss accuracy.
  • Crosstalk measurement – NEXT and ACR-F.
  • Length and propagation delay.
  • Compliance against the current TIA and ISO limits.
  • Main and remote units, individually and as a pair.

FAQs

How often should this be calibrated? Most quality systems work on an annual interval, though how hard the instrument is used and how critical its readings are should drive that decision rather than the calendar alone.

Do I get as-found data, or only the final result? Both. As-found readings are recorded before any adjustment and as-left afterwards, which is what tells you whether the instrument was in tolerance during the work you already did with it.

Calibration is documented and returned with the instrument. If we find a fault that calibration cannot correct, we quote the repair before going any further. Email us or submit a service request.