HVI VLF Cable Test System Repair

Status: Current Production

Overview

The HVI VLF Series provides very low frequency (0.1 Hz, 0.05 Hz, and 0.01 Hz) AC test voltage for medium and high-voltage cable withstand testing and diagnostics. VLF testing is the preferred method for XLPE and EPR cable testing because it stresses insulation similarly to power frequency without the damaging space charge effects of DC testing. The CM suffix indicates cosine-rectangular waveform with metering, CMF adds filtration, and E suffix indicates enhanced sine wave models with integrated tan delta diagnostics. Output voltages range from 28 kVpeak to 200 kVpeak. The TD-34E and TDB-60 add full tan delta and partial discharge diagnostic capability.

Specifications

Parameter Value
Output Voltage 28 kVpeak to 200 kVpeak (model dependent)
Frequency 0.1 Hz, 0.05 Hz, 0.01 Hz
Waveform Cosine-rectangular (CM/CMF) or true sine wave (E)
Diagnostics Tan delta and PD measurement (E models, TD-34E, TDB-60)
Key Features IEEE 400.2 compliant, cable withstand testing, VLF diagnostics, portable design

Models We Repair

Select your model below to request a repair. If your exact configuration isn’t listed, choose the closest match — the evaluation and repair process is the same across all HVI VLF Series configurations.

Model Description Service
HVI VLF-200CMF 200 kVpeak VLF cable tester, filtered Request Repair
HVI VLF-12011CMF 120 kVpeak VLF cable tester, filtered Request Repair
HVI VLF-90CMF 90 kVpeak VLF cable tester, filtered Request Repair
HVI VLF-65CMF 65 kVpeak VLF cable tester, filtered Request Repair
HVI VLF-65E 65 kVpeak VLF sine wave with diagnostics Request Repair
HVI VLF-6022CM 60 kVpeak VLF cable tester Request Repair
HVI VLF-50CMF 50 kVpeak VLF cable tester, filtered Request Repair
HVI VLF-4022CM 40 kVpeak VLF cable tester Request Repair
HVI VLF-34E 34 kVpeak VLF sine wave with diagnostics Request Repair
HVI VLF-30CM 30 kVpeak VLF cable tester Request Repair
HVI VLF-28CM 28 kVpeak VLF cable tester Request Repair
HVI TD-34E VLF tan delta diagnostic test set Request Repair
HVI TDB-60 VLF cable test set with diagnostics Request Repair

Common HVI VLF Series Failures We Repair

  • High-voltage output stage failure from cable flashover events
  • Voltage regulation circuit degradation causing waveform distortion
  • HV cable and reactor insulation breakdown
  • Diagnostic measurement circuit calibration drift (E models)
  • Control processor or display failures
  • Battery/charger system failures on portable units
  • Cooling system failures from sustained high-output testing

Our technicians perform component-level diagnostics on every HVI VLF Series unit. High-voltage test equipment requires specialized repair expertise and calibration equipment — we have the tools and experience to restore your instrument to factory specifications.

Calibration

Every HVI VLF Series repair includes NIST-traceable calibration. We verify output voltage accuracy, metering accuracy, and all safety functions against our reference standards and provide a detailed calibration certificate documenting measured performance against the manufacturer’s published specifications.

Who Uses the HVI VLF Series?

The HVI VLF-28CM / VLF-30CM / VLF-34E / VLF-4022CM / VLF-50CMF / VLF-6022CM / VLF-65CMF / VLF-65E / VLF-90CMF / VLF-12011CMF / VLF-200CMF Very Low Frequency Cable Test Systems are used by electric utilities, cable testing contractors, underground distribution maintenance, high-voltage cable installation, and NETA-certified testing companies.

Our Repair Process

  1. Ship Your Instrument: Send your HVI VLF Series to our facility from anywhere in the US. We provide prepaid shipping labels on request.
  2. Free Evaluation: Our technicians perform a complete diagnostic assessment and provide a firm, no-obligation repair quote.
  3. Expert Repair: Upon approval, we perform component-level repair using OEM-grade parts.
  4. NIST-Traceable Calibration: Full calibration with documented results across all critical parameters.
  5. Return Shipment: Your instrument is securely packaged and returned with calibration certificate, repair documentation, and our 90-day warranty.

Request a Repair

Contact us for professional HVI VLF Series repair and calibration. Our team is ready to evaluate your instrument and provide a no-obligation quote.

Email: info@junecompany.com | All repairs include a 90-day parts and labor warranty.