Keysight Infiniium S-Series & V-Series Oscilloscope Repair

Status: Keysight Infiniium repair covers the full current-production S-Series and V-Series oscilloscope range. We repair and calibrate all of them.

Common Keysight Infiniium Problems We Fix

  • Channel dead, noisy, or reading wrong — high-bandwidth input amplifier or sampler failure
  • Vertical accuracy off / fails self-cal — ADC circuit degradation
  • Won’t boot or load the Infiniium app — hard drive or SSD failure in the Windows acquisition system
  • Display or touchscreen not responding, cracked, or dead
  • Shuts down under load / thermal protection trips — fan assembly failure
  • Won’t power on — power supply module degradation
  • Acquisition errors or crashes — high-speed memory module failure
  • Won’t connect to the network / LAN interface faults

Don’t see your exact problem? We handle all Keysight Infiniium repair needs — email us and describe what’s happening.

Keysight Infiniium Models We Repair

Model Description Service
Keysight DSAV334A 33 GHz, 4 ch V-Series Advanced Request Repair
Keysight MSOV334A 33 GHz, 4+16 ch V-Series Request Repair
Keysight DSOV334A 33 GHz, 4 ch V-Series Request Repair
Keysight DSAV254A 25 GHz, 4 ch V-Series Advanced Request Repair
Keysight MSOV254A 25 GHz, 4+16 ch V-Series Request Repair
Keysight DSOV254A 25 GHz, 4 ch V-Series Request Repair
Keysight DSAV204A 20 GHz, 4 ch V-Series Advanced Request Repair
Keysight MSOV204A 20 GHz, 4+16 ch V-Series Request Repair
Keysight DSOV204A 20 GHz, 4 ch V-Series Request Repair
Keysight DSAV164A 16 GHz, 4 ch V-Series Advanced Request Repair
Keysight MSOV164A 16 GHz, 4+16 ch V-Series Request Repair
Keysight DSOV164A 16 GHz, 4 ch V-Series Request Repair
Keysight DSAV134A 13 GHz, 4 ch V-Series Advanced Request Repair
Keysight MSOV134A 13 GHz, 4+16 ch V-Series Request Repair
Keysight DSOV134A 13 GHz, 4 ch V-Series Request Repair
Keysight DSAV084A 8 GHz, 4 ch V-Series Advanced Request Repair
Keysight MSOV084A 8 GHz, 4+16 ch V-Series Request Repair
Keysight DSOV084A 8 GHz, 4 ch V-Series Request Repair
Keysight MSOS804A 8 GHz, 4+16 ch S-Series Request Repair
Keysight DSOS804A 8 GHz, 4 ch S-Series Request Repair
Keysight MSOS604A 6 GHz, 4+16 ch S-Series Request Repair
Keysight DSOS604A 6 GHz, 4 ch S-Series Request Repair
Keysight MSOS404A 4 GHz, 4+16 ch S-Series Request Repair
Keysight DSOS404A 4 GHz, 4 ch S-Series Request Repair
Keysight MSOS254A 2.5 GHz, 4+16 ch S-Series Request Repair
Keysight DSOS254A 2.5 GHz, 4 ch S-Series Request Repair
Keysight MSOS204A 2 GHz, 4+16 ch S-Series Request Repair
Keysight DSOS204A 2 GHz, 4 ch S-Series Request Repair
Keysight MSOS104A 1 GHz, 4+16 ch S-Series Request Repair
Keysight DSOS104A 1 GHz, 4 ch S-Series Request Repair
Keysight MSOS054A 500 MHz, 4+16 ch S-Series Request Repair
Keysight DSOS054A 500 MHz, 4 ch S-Series Request Repair

How to Send In Your Keysight Infiniium

  1. Tell us what’s wrong. Email us or submit a service request with your model and the problem.
  2. Ship it to us. Send your instrument from anywhere in the US — we provide prepaid shipping labels on request.
  3. Get a firm quote. We evaluate it and send a no-obligation repair quote. No work is done until you approve.

Email: info@junecompany.com | All repairs include NIST-traceable calibration and a 90-day parts-and-labor warranty.

Frequently Asked Questions

How much does Keysight Infiniium repair cost?

Repairs start with a flat evaluation fee that’s credited toward your repair cost. After we diagnose the instrument, you get a firm quote before any work begins — no surprises.

How long does the repair take?

Most Infiniium repairs are finished within 5–10 business days of arrival, with expedited turnaround available if you need it back fast. High-bandwidth V-Series channel repairs can run longer — we’ll tell you up front with the quote.

One of my channels is dead or reading wrong — can you fix it?

Yes. Input channel amplifier and sampler failures are one of the most common Infiniium faults, especially on the high-bandwidth V-Series, and channels are restored to full measurement accuracy.

My vertical accuracy is off or it fails self-calibration — can you recalibrate it?

Yes. ADC and front-end degradation that throws off vertical accuracy is repairable, then verified against our reference standards and documented on a NIST-traceable certificate.

It won’t boot or won’t load the Infiniium application — can you recover it?

Yes. These run a Windows-based acquisition system, and hard-drive or SSD failures that stop the scope from booting or loading the Infiniium app are a routine repair, restored to a working, calibrated state.

It overheats and shuts down — is that repairable?

Yes. Fan assembly failure that triggers thermal-protection shutdowns is common and fully repairable, restored so the instrument stays within its thermal limits under load.

What if my exact model isn’t listed?

We service every Infiniium S-Series and V-Series configuration, DSO, MSO, and DSA variants alike. If your model isn’t in the table, pick the closest match or email us — the process is the same.

Who uses the Keysight Infiniium?

Semiconductor design teams, high-speed serial interface validation engineers, compliance test labs, signal-integrity groups, data-center interconnect developers, and aerospace/defense programs rely on the Infiniium S-Series and V-Series for high-speed digital and serial-data measurement, and trust independent Keysight Infiniium repair to keep them in service. For full manufacturer specifications, see Keysight’s S-Series product page.