Chroma 61809 Grid Simulator Repair and Calibration

$245.00

🛡️ 90-Day Warranty ✓ Fee Credited to Repair ⚡ No Forms Needed

Authorized Chroma 61809 repair, calibration, and restoration services. We address leakage current measurement drift and other common grid simulator repair and calibration faults.

đź“‹ How It Works

  1. Submit Request – Pay evaluation fee & provide equipment details
  2. Ship to Us – Send your equipment to our Oregon facility
  3. We Evaluate – Detailed diagnosis & repair estimate
  4. Fee Credited – Your evaluation fee applies to repair cost
  5. We Repair – Professional repair with 90-day warranty
  • đź”§ Fast Turnaround: Most repairs are completed within 1–3 business days.
  • 📏 Precision Calibration: NIST-traceable calibrations included for most repairs.
  • 🛡️ Warranty: 90-day warranty on all repairs.
  • 📝 Transparency: Detailed evaluation and repair estimate before work begins.
âś“ Evaluation Fee Credited Toward Repair

This evaluation fee is applied as credit toward your final repair cost. After we evaluate your equipment, you'll receive a detailed estimate before any repair work begins.

Description

Chroma 61809 Grid Simulator Repair and Calibration

The Chroma 61809 is a regenerative grid simulator / programmable AC source — it generates programmable AC and emulates grid conditions and disturbances (with energy regeneration) for testing inverters, EV chargers, and grid-tied equipment. As a high-power regenerative AC system, its faults concentrate in the power stage, the regenerative/control electronics, and waveform generation — not the hipot/leakage faults its category label implies.

June Company repairs and calibrates the Chroma 61809 for grid-tie, inverter, and EV test labs.

Common Chroma 61809 problems we fix

  • Output-regulation failure — output won’t hold the programmed setpoint, the regulation loop repaired and recalibrated.
  • Regenerative / bidirectional faults — the power electronics that return energy, repaired.
  • Waveform or grid-emulation off — waveform-generation faults corrupting test profiles, corrected.
  • Measurement drift — the built-in metering, recalibrated against standards.
  • Cooling or control-interface faults.

FAQs

My 61809 won’t regulate or emulate grid conditions — fixable? Yes. Regulation, power-stage, and waveform faults are repairable, then verified so it reproduces AC and grid profiles accurately, with a NIST-traceable certificate.

Is the regenerative mode verified? Yes — source and regeneration are both checked.

Every repair includes NIST-traceable calibration and a 90-day parts-and-labor warranty. Email us or submit a service request.

Brand

Chroma Repair

Chroma ATE Inc. is a global leader in providing precision test and measurement instrumentation. They offer a wide range of products that cater to various industries, including electronics, electric vehicles, solar energy, LED, and power supplies. Here is an overview of Chroma's key product lines and their functionalities: 1. Programmable Power Supplies Chroma offers a variety of programmable power supplies for different testing applications. DC Power Supplies 62000P Series: High power density, low noise, and fast transient response, ideal for testing electric vehicle components and power modules. 62000H Series: High-voltage DC power supplies used in photovoltaic (PV) inverter testing, battery simulation, and aerospace applications. AC Power Sources 61500 Series: Programmable AC power sources with comprehensive features such as harmonic generation, arbitrary waveform generation, and measurement functions. Used in testing household appliances, avionics, and telecommunications equipment. 61600 Series: High-performance AC power sources suitable for power electronics testing, including grid-tied inverter testing and uninterruptible power supply (UPS) testing. 2. Electronic Loads Chroma provides electronic loads for testing power supplies, batteries, and other power devices. DC Electronic Loads 63000 Series: Modular electronic loads that provide high accuracy and flexibility, ideal for power supply and battery testing. 63200A Series: High-power DC electronic loads used in testing fuel cells, power electronic components, and high-power DC/DC converters. AC Electronic Loads 63800 Series: AC electronic loads designed for testing UPS systems, grid-tied inverters, and AC power sources. They offer features like power factor adjustment and regenerative capabilities. 3. Battery Testing Systems Chroma offers comprehensive battery testing solutions for various battery types and applications. 17020 Series Battery Charge/Discharge Test System: Designed for testing lithium-ion batteries, providing high precision and reliability for charge/discharge cycles, life cycle testing, and capacity testing. 17040 Series Regenerative Battery Pack Test System: Used for testing battery packs and modules with energy regenerative capabilities, making it suitable for electric vehicle and energy storage applications. 4. Automated Test Systems (ATE) Chroma’s ATE systems are designed for high-volume production testing and quality assurance. 8000 ATS Power Supply Test System: Comprehensive test system for power supplies, including AC/DC, DC/DC, and battery chargers. It provides automated testing for functional and safety compliance. ATE for EV Components EV/HEV Test Systems: Automated test systems specifically designed for testing electric vehicle components such as motor drivers, on-board chargers, and power electronics.