Evident BTX III XRD Analyzer Repair

evident scientific repair logo

$245.00

🛡️ 90-Day Warranty ✓ Fee Credited to Repair ⚡ No Forms Needed

Component-level Evident BTX III repair by certified technicians — X-ray tube, CCD detector, sample chamber, cooling and control electronics.

đź“‹ How It Works

  1. Submit Request – Pay evaluation fee & provide equipment details
  2. Ship to Us – Send your equipment to our Oregon facility
  3. We Evaluate – Detailed diagnosis & repair estimate
  4. Fee Credited – Your evaluation fee applies to repair cost
  5. We Repair – Professional repair with 90-day warranty
  • đź”§ Fast Turnaround: Most repairs are completed within 1–3 business days.
  • 📏 Precision Calibration: NIST-traceable calibrations included for most repairs.
  • 🛡️ Warranty: 90-day warranty on all repairs.
  • 📝 Transparency: Detailed evaluation and repair estimate before work begins.
âś“ Evaluation Fee Credited Toward Repair

This evaluation fee is applied as credit toward your final repair cost. After we evaluate your equipment, you'll receive a detailed estimate before any repair work begins.

Description

Evident BTX III XRD Analyzer Repair

The BTX III is the benchtop counterpart to the TERRA II, delivering the same analytical performance in a 12.5 kg laboratory package roughly 30 by 17 by 47 cm. It runs a Cu target at 30 kV and 20 W, covers about 5 to 55 degrees 2-theta at around 0.2 degrees FWHM into a 1024 by 256 pixel Peltier-cooled 2D CCD, and offers XRF from 3 to 25 keV, with SwiftMin providing automated phase identification and quantification on the instrument.

June Company’s certified technicians repair the BTX III for analytical laboratories, cement and minerals producers, universities and industrial quality control groups. We diagnose and repair at the board and component level, and every instrument is functionally verified before it ships back.

Common BTX III problems we fix

  • X-ray tube faults — reduced output or complete failure, extending count times or halting analysis.
  • CCD detector faults — dead pixels, elevated noise or cooling loss degrading peak resolution.
  • Cooling system faults — Peltier performance dropping, which raises the noise floor as the instrument runs.
  • Sample chamber faults — the sample presentation system failing to hold or vibrate powder correctly.
  • Calibration and alignment drift — 2-theta shift producing misidentified phases or poor quantification.
  • Control electronics faults — board-level failures that stop acquisition or corrupt data.
  • Software and storage faults — SwiftMin not launching, libraries not loading or results not writing.
  • Communication faults — wireless or wired connections to the host PC dropping mid-run.
  • Safety interlock faults — interlocks failing and correctly preventing operation.
  • Power supply faults — instability in the high-voltage supply, which shows as inconsistent results rather than a clean failure.

FAQs

Is a BTX III economical to repair against replacement? Almost always. The mechanical platform is durable, and most faults are the detector cooling, the tube or the sample chamber rather than the whole instrument. We quote before any work.

Can you supply a calibration report? We verify against reference standards before return and report the results. A formal accredited calibration is a separate service we can advise on.

Do you repair the portable TERRA II as well? Yes. They share most of their analytical hardware.

Every repair is backed by a 90-day parts-and-labor warranty, with a firm quote before any work begins. Email us or submit a service request.

Brand

Evident Scientific Repair

Vanta Handheld XRF Analyzer Repair The Vanta series of handheld XRF analyzers, including the Vanta Max, Vanta Core, and Vanta Element, are portable elemental analysis instruments designed for fast, non-destructive identification and analysis of materials. Their rugged handheld design, streamlined operation, and connectivity features make them suitable for demanding field and industrial applications. June Company repairs Vanta handheld XRF analyzers at the component level. Our repair process includes troubleshooting the instrument to isolate electronic and hardware failures, testing and repairing defective circuitry and components, and replacing failed components where practical. Following repair, the analyzer is functionally tested to verify proper operation and reliable performance.
evident scientific repair logo

Shipping & Returns

Packing your equipment. You are responsible for packaging equipment adequately for transit. We strongly recommend the original manufacturer’s case, or double-boxing with at least two inches of shock-absorbing material on all six sides. We return your equipment in the packaging it arrived in, so please send it in packaging that will survive the return trip as well. If your packaging is damaged or inadequate for the return, we will substitute suitable packaging and may charge the cost of materials.

Insurance. Equipment is not insured by June Company while in transit. We strongly recommend insuring your shipment for its full replacement value.

Risk of loss. Risk of loss remains with you until your equipment is received at our facility, and transfers back to you when your repaired unit is delivered to the carrier (F.O.B. shipping point). June Company is not responsible for equipment lost, delayed, misdelivered, or damaged in transit, in either direction.

Return label. A prepaid and preprinted return shipping label should be included with your shipment. If one is not included, we will provide one.

Transit damage. Damage occurring in transit is the responsibility of the carrier. It is not a warranty defect and is not covered by the 90-day repair warranty. Any claim must be filed by you with the carrier; we will supply photographs and documentation to support it at no charge.

Full details: Terms & Conditions, Section 6 · Return Policy

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.