Status: Current Production
Overview
The Vitrek PA900 Series modular power analyzers provide precision power measurement for energy efficiency testing, compliance testing, and power supply characterization. The PA900 base mainframe accepts up to four measurement channels. The AD-suffix modules (PA901AD–PA904AD) provide standard power analysis. The VT-suffix modules (PA911VT–PA914VT) add voltage-only and transducer measurement capability. The UT-suffix modules (PA921UT–PA924UT) provide ultra-high accuracy for calibration laboratory use. Channel counts scale from 1 to 4 channels per mainframe, enabling single-phase to three-phase power analysis with neutral monitoring. The PA900 platform supports simultaneous measurement of voltage, current, power, power factor, harmonics, and energy with accuracy suitable for ENERGY STAR, DOE, and IEC 62301 standby power compliance testing.
Specifications
| Parameter | Value |
|---|---|
| Channels | 1 to 4 per mainframe |
| Voltage Range | Up to 1000 Vrms |
| Current Range | Up to 40 Arms direct, external shunt for higher |
| Basic Accuracy | 0.04% (UT modules) |
| Bandwidth | DC to 1 MHz |
| Harmonics | Up to 100th harmonic |
| Key Features | Modular architecture, ENERGY STAR compliance, standby power measurement, harmonic analysis, data logging, USB/GPIB/LAN interfaces |
Models We Repair
Select your model below to request a repair. If your exact configuration isn’t listed, choose the closest match — the evaluation and repair process is the same across all Vitrek PA900 Series configurations.
| Model | Description | Service |
|---|---|---|
| Vitrek PA924UT | 4-channel ultra-precision power analyzer | Request Repair |
| Vitrek PA923UT | 3-channel ultra-precision power analyzer | Request Repair |
| Vitrek PA922UT | 2-channel ultra-precision power analyzer | Request Repair |
| Vitrek PA921UT | 1-channel ultra-precision power analyzer | Request Repair |
| Vitrek PA920 | Ultra-precision mainframe | Request Repair |
| Vitrek PA914VT | 4-channel power analyzer with transducer input | Request Repair |
| Vitrek PA913VT | 3-channel power analyzer with transducer input | Request Repair |
| Vitrek PA912VT | 2-channel power analyzer with transducer input | Request Repair |
| Vitrek PA911VT | 1-channel power analyzer with transducer input | Request Repair |
| Vitrek PA910 | VT-series mainframe | Request Repair |
| Vitrek PA904AD | 4-channel standard power analyzer | Request Repair |
| Vitrek PA903AD | 3-channel standard power analyzer | Request Repair |
| Vitrek PA902AD | 2-channel standard power analyzer | Request Repair |
| Vitrek PA901AD | 1-channel standard power analyzer | Request Repair |
| Vitrek PA900 | AD-series mainframe | Request Repair |
Common Vitrek PA900 Series Failures We Repair
- Input channel module failures from overvoltage or overcurrent events
- Current shunt degradation affecting measurement accuracy
- Voltage divider circuit calibration drift
- Mainframe power supply failures
- Display or touchscreen failures
- Communication interface failures (USB, GPIB, LAN)
- ADC module calibration drift
- Module connector intermittent contact issues
Our technicians perform component-level diagnostics on every Vitrek PA900 Series unit. We identify and repair the specific failed components rather than replacing entire assemblies when possible, reducing your repair cost and turnaround time.
Calibration
Every Vitrek PA900 Series repair includes NIST-traceable calibration. We verify all critical measurement parameters against our reference standards and provide a detailed calibration certificate documenting measured performance against the manufacturer’s published specifications.
Who Uses the Vitrek PA900 Series?
The Vitrek PA900 / PA901AD–PA904AD / PA910 / PA911VT–PA914VT / PA920 / PA921UT–PA924UT Power Analyzers are used by power supply manufacturing, energy efficiency compliance testing, appliance testing laboratories, ENERGY STAR certification, calibration laboratories, and power electronics R&D.
Our Repair Process
- Ship Your Instrument: Send your Vitrek PA900 Series to our facility from anywhere in the US. We provide prepaid shipping labels on request.
- Free Evaluation: Our technicians perform a complete diagnostic assessment and provide a firm, no-obligation repair quote.
- Expert Repair: Upon approval, we perform component-level repair using OEM-grade parts.
- NIST-Traceable Calibration: Full calibration with documented results across all critical parameters.
- Return Shipment: Your instrument is securely packaged and returned with calibration certificate, repair documentation, and our 90-day warranty.
Request a Repair
Contact us for professional Vitrek PA900 Series repair and calibration. Our team is ready to evaluate your instrument and provide a no-obligation quote.
Email: info@junecompany.com | All repairs include a 90-day parts and labor warranty.