Lambda GH600-1.7 Power Supply Repair
The TDK-Lambda GH600-1.7 (Genesys series) is a programmable DC power supply — 600 V / 1.7 A, a high-voltage-end Genesys rack supply used in test systems and production for programmable DC sourcing where higher voltage at modest current is needed. Its character is regulated higher-voltage DC under programmable control, so faults concentrate in the output stage, regulation, and control.
June Company repairs and calibrates the Lambda GH600-1.7 for electronics labs, production test, and R&D teams.
Common Lambda GH600-1.7 problems we fix
- Won’t reach 600 V or output collapses — output-stage failure, rebuilt for full rated output.
- Output unstable or noisy — regulation-loop degradation, recalibrated for clean DC.
- Programming/communication faults — the remote interface that stops ATE control, restored.
- Readback inaccurate — voltage/current measurement drift, recalibrated.
- Fan or thermal-shutdown faults — cooling service.
FAQs
My GH600 won’t reach 600 V — fixable? Yes. Output-stage and regulation faults are repairable, then verified so it sources and reads back full rated output, with a NIST-traceable certificate.
Is the remote interface verified? Yes — programming and readback are checked for ATE use.
Every repair includes NIST-traceable calibration and a 90-day parts-and-labor warranty. Email us or submit a service request.
Shipping & Returns
Packing your equipment. You are responsible for packaging equipment adequately for transit. We strongly recommend the original manufacturer’s case, or double-boxing with at least two inches of shock-absorbing material on all six sides. We return your equipment in the packaging it arrived in, so please send it in packaging that will survive the return trip as well. If your packaging is damaged or inadequate for the return, we will substitute suitable packaging and may charge the cost of materials.
Insurance. Equipment is not insured by June Company while in transit. We strongly recommend insuring your shipment for its full replacement value.
Risk of loss. Risk of loss remains with you until your equipment is received at our facility, and transfers back to you when your repaired unit is delivered to the carrier (F.O.B. shipping point). June Company is not responsible for equipment lost, delayed, misdelivered, or damaged in transit, in either direction.
Return label. A prepaid and preprinted return shipping label should be included with your shipment. If one is not included, we will provide one.
Transit damage. Damage occurring in transit is the responsibility of the carrier. It is not a warranty defect and is not covered by the 90-day repair warranty. Any claim must be filed by you with the carrier; we will supply photographs and documentation to support it at no charge.
Full details: Terms & Conditions, Section 6 · Return Policy