Agilent 55B AA Atomic Absorption System Repair

Agilent Lab Products Repair

$245.00

🛡️ 90-Day Warranty ✓ Fee Credited to Repair ⚡ No Forms Needed

Certified Agilent 55B AA repair — fast turnaround, 90-day warranty included. Service covers optical system realignment, detector replacement, burner assembly overhaul, and autosampler mechanism repair.

đź“‹ How It Works

  1. Submit Request – Pay evaluation fee & provide equipment details
  2. Ship to Us – Send your equipment to our Oregon facility
  3. We Evaluate – Detailed diagnosis & repair estimate
  4. Fee Credited – Your evaluation fee applies to repair cost
  5. We Repair – Professional repair with 90-day warranty
  • đź”§ Fast Turnaround: Most repairs are completed within 1–3 business days.
  • 📏 Precision Calibration: NIST-traceable calibrations included for most repairs.
  • 🛡️ Warranty: 90-day warranty on all repairs.
  • 📝 Transparency: Detailed evaluation and repair estimate before work begins.
âś“ Evaluation Fee Credited Toward Repair

This evaluation fee is applied as credit toward your final repair cost. After we evaluate your equipment, you'll receive a detailed estimate before any repair work begins.

Description

Agilent 55B AA Atomic Absorption System Repair

The Agilent 55B AA is a flame atomic absorption spectrometer — a lab analytical instrument that measures the concentration of metal elements in a sample by aspirating it into a flame and measuring light absorption from an element-specific lamp. Its performance depends on the optical system, the detector, the burner/nebulizer, and the lamp circuitry, which is where service focuses.

June Company repairs and calibrates the Agilent 55B AA for analytical, environmental, and QC labs.

Common Agilent 55B AA problems we fix

  • Optical-system realignment — drifted or misaligned optics reducing sensitivity, realigned for correct light throughput.
  • Detector replacement — a degraded or failed detector (photomultiplier) reducing signal, replaced.
  • Burner / nebulizer faults — clogged or misadjusted burner/nebulizer affecting the flame and sample uptake, serviced.
  • Lamp-circuit faults — the hollow-cathode lamp drive not energizing correctly, repaired.
  • Readings drift or won’t calibrate — recalibrated against reference standards.

FAQs

My 55B AA lost sensitivity — fixable? Yes. Optical, detector, and burner faults are repairable; we realign and service the system, then verify calibration so concentration measurements are accurate, with documented results.

Do you service the burner and nebulizer? Yes — they’re a core part of the service.

Every repair includes calibration verification and a 90-day parts-and-labor warranty. Email us or submit a service request.