Hipotronics ISO/IEC 17025 Calibration | NIST-Traceable
June Company provides accredited Hipotronics calibration carried out to ISO/IEC 17025 requirements, with measurements traceable to NIST. Regular calibration keeps high-voltage test equipment operating safely and accurately within the manufacturer’s published specifications ā which matters most on the hipot testers, dielectric test sets, and HV dividers that protect both your results and your operators.
Hipotronics Models We Calibrate
| Model | Description |
|---|---|
| 100 HVT | Hipot tester, AC, >60 kV |
| 260-A | Hipot tester, DC, >25ā60 kV |
| 60HVT-A | Hipot tester, AC, >26ā60 kV |
| 705-1 | Hipot tester, AC/DC, ā¤6 kV |
| 705-2 | Hipot tester, AC/DC, ā¤6 kV |
| 710-100 | Hipot tester, AC, >60 kV |
| 710-2-A | Dielectric test set, AC, >5ā25 kV |
| 710-5 | Hipot tester, AC, >6ā25 kV |
| 7100-10 | Dielectric test set, AC, >60 kV |
| 750-2 | Dielectric test set, AC, >25ā60 kV |
| 750-2D149 | Hipot tester, AC, >26ā60 kV |
| 760-2HVT | Hipot tester, AC, >26ā60 kV |
| 775-5 | Hipot tester, AC, >60 kV |
| 8120-5PL | Hipot tester, DC, >60 kV |
| 860PL | Hipot tester, DC, >25ā60 kV |
| 880PL | Hipot tester, DC, >60 kV |
| 880PL-10MA-A | Hipot tester, DC, >60 kV |
| H300B | Hipot tester, AC/DC, ā¤6 kV |
| H301B | Hipot tester, AC/DC/IR, ā¤6 kV |
| H303B | Hipot tester, AC/DC, ā¤6 kV |
| H306B | Hipot tester, AC/DC/IR, >6ā25 kV |
| H800PL | Hipot tester, DC, >6ā25 kV |
| H860PL | Hipot tester, AC, >26ā60 kV |
| H880PL | Hipot tester, DC, >60 kV |
| HA3AT | Hipot tester, AC, ā¤6 kV |
| HD-103 | Hipot tester, AC/DC, ā¤6 kV |
| HD100 | Hipot tester, AC/DC, >6ā25 kV |
| HD103A | Hipot tester, AC/DC, ā¤6 kV |
| HD106 | Hipot tester, AC/DC, ā¤6 kV |
| HD115 | Hipot tester, AC/DC/IR, >6ā25 kV |
| HD125 | Hipot tester, AC/DC, >6ā25 kV |
| HD125-A | Hipot tester, AC/DC, >6ā25 kV |
| HD140 | Hipot tester, AC/DC/IR, >25ā60 kV |
| HDA3 | Hipot tester, AC, ā¤6 kV |
| HDB4AT-CT | Hipot tester, DC, ā¤6 kV |
| HM3A | Insulation tester / megohmmeter, analog, 500 Vā1000 V, >1 GĪ© |
| HM6B | Insulation tester / megohmmeter, digital, ā¤1000 V, ā¤1 GĪ© |
| HV5 | Insulation tester / megohmmeter, digital, >2500ā5000 V, >1 GĪ©ā100 GĪ© |
| HVM5-A | Insulation tester / megohmmeter, analog, >2500ā5000 V, >1 GĪ© |
| KV100A | HV divider, AC/DC, >60 kV, ā„0.4% |
| KVM100 | HV divider, AC/DC, >60 kV, ā„0.4% |
| KVM100D | HV divider, AC/DC, >60 kV, ā„0.4% |
| ML-100A | Micro-ohmmeter, >0.5% accuracy, ā¤1 Ī©, 1 Ī©ā10 MĪ© |
| OC50A | Liquid dielectric hipot tester, AC, >26ā60 kV |
| OC60A | Liquid dielectric hipot tester, AC, >26ā60 kV |
| OC60D | Liquid dielectric hipot tester, AC, >26ā60 kV |
| OC60D-A | Liquid dielectric hipot tester, AC, >26ā60 kV |
| OC60E-A | Liquid dielectric hipot tester, AC, >26ā60 kV |
| R2B | DC power supply, bench, single output, ā¤20 A |
Don’t see your exact model? We calibrate the full Hipotronics range ā email us with your model and we’ll confirm.
How to Send In Your Hipotronics Instrument
- Tell us your model. Email us or submit a service request with your model and what you need calibrated.
- Ship it to us. Send your instrument from anywhere in the US ā we provide prepaid shipping labels on request.
- Get it back, documented. We calibrate it, verify performance against the manufacturer’s specs, and return it with a NIST-traceable calibration certificate.
Email: info@junecompany.com | All calibrations are traceable to NIST and include a 90-day warranty.
Frequently Asked Questions
How much does Hipotronics calibration cost?
Calibration is a flat per-instrument rate that depends on the model and ranges involved. Email us with your model and we’ll send a firm quote before anything ships.
How long does calibration take?
Most Hipotronics calibrations are completed within 5ā10 business days of arrival, with expedited turnaround available if you need it back fast.
Is your calibration ISO/IEC 17025 accredited and NIST-traceable?
Yes. ISO/IEC 17025 is the international standard for calibration laboratory competence, and “NIST-traceable” means every measurement chains back to national reference standards. Your certificate documents the measured results against the manufacturer’s published specifications.
How often should I calibrate my hipot tester or HV divider?
An annual calibration interval is typical for high-voltage test equipment, though your quality system or the standard you test to may require a different cycle. Safety-critical or heavily used instruments are often calibrated more frequently.
My instrument reads out of tolerance ā can you repair it as well as calibrate it?
Yes. If we find a unit out of tolerance during calibration, we’ll quote the repair, restore it to specification, and then calibrate it ā so it comes back both working and certified.
Do I receive a calibration certificate?
Yes. Every calibration includes a detailed certificate showing the measured performance against specification, with results traceable to NIST.
What if my exact model isn’t listed?
The table covers the Hipotronics models we calibrate most often, but it isn’t exhaustive. We service the full Hipotronics high-voltage line ā email us and we’ll confirm yours.
Who uses Hipotronics high-voltage equipment?
Electric utilities, cable and transformer manufacturers, electrical test laboratories, switchgear and motor shops, and industrial maintenance teams rely on Hipotronics hipot testers, dielectric test sets, and HV dividers for high-voltage withstand and insulation testing.