Overview
Megger circuit breaker test sets verify the timing, motion, and contact resistance of medium and high-voltage circuit breakers. The PS-9116/9130/9160 series provides multi-channel timing analysis with motion measurement for SF6, vacuum, and oil circuit breakers. The DET2/3 ground resistance tester measures earth electrode resistance using fall-of-potential, stakeless, and attached rod methods. Additional specialty instruments include the PAT portable appliance testers, PMM-1 multimeter, and power quality analyzers.
Specifications
| Parameter | Value |
|---|---|
| CB Timing | Multi-channel timing, motion analysis, coil current measurement |
| Ground Testing | 2, 3, and 4-pole earth resistance measurement, stakeless clamp method |
| Key Features | Circuit breaker timing and motion analysis, ground resistance measurement, automated test sequences |
Models We Repair
Select your model below to request a repair. If your exact model isn’t listed, choose the closest match — the evaluation and repair process is the same across all Megger Circuit Breaker and Ground Testers configurations.
| Model | Description | Service |
|---|---|---|
| Megger PS-9160 | Circuit breaker test set — multi-channel timing and motion | Request Repair |
| Megger PS-9130 | Circuit breaker test set | Request Repair |
| Megger PS-9116 | Circuit breaker test set | Request Repair |
| Megger DET2/3 | Ground resistance tester | Request Repair |
| Megger PAT450 | Portable appliance tester | Request Repair |
| Megger PAT320 | Portable appliance tester | Request Repair |
| Megger PMM-1 | Multimeter | Request Repair |
| Megger MPQ1000 | Power quality analyzer | Request Repair |
| Megger Tan Delta Meter | Power factor / tan delta meter | Request Repair |
Common Megger Circuit Breaker and Ground Testers Failures We Repair
- Timing channel measurement circuit failures
- Motion transducer interface degradation
- Ground tester electrode drive circuit faults
- Display or control panel failures
- Communication interface failures
- Battery performance degradation
Our technicians perform component-level diagnostics on every Megger Circuit Breaker and Ground Testers unit. We don’t just replace boards — we identify and repair the specific failed components, saving you the cost of full module replacements when possible.
Calibration
Every Megger Circuit Breaker and Ground Testers repair includes NIST-traceable calibration. We verify all critical measurement and output functions against our reference standards and provide a detailed calibration certificate documenting measured performance against the manufacturer’s published specifications.
Who Uses Megger Circuit Breaker and Ground Testers?
The Megger PS-9116 / PS-9130 / PS-9160 Circuit Breaker Test Sets, DET2/3 Ground Tester, and Specialty Instruments are used by substation maintenance, circuit breaker testing contractors, utility grounding programs, and industrial electrical safety testing.
Our Repair Process
- Ship Your Instrument: Send your Megger Circuit Breaker and Ground Testers to our facility from anywhere in the US. We provide prepaid shipping labels on request.
- Free Evaluation: Our technicians perform a complete diagnostic assessment and provide a firm, no-obligation repair quote.
- Expert Repair: Upon approval, we perform component-level repair using OEM-grade parts.
- NIST-Traceable Calibration: Full calibration with documented results across all critical parameters.
- Return Shipment: Your instrument is securely packaged and returned with calibration certificate, repair documentation, and our 90-day warranty.
Request a Repair
Contact us for professional Megger Circuit Breaker and Ground Testers repair and calibration. Our team is ready to evaluate your instrument and provide a no-obligation quote.
Email: info@junecompany.com | All repairs include a 90-day parts and labor warranty.